Sunday, December 30, 2012

Three Phase Traction Motor


Audit of following Work Instructions was done in TM Shop. Report is as follows:-

Assembly of short circuit cage( W 21.404):-
Points noticed:-
  • Initial insertion of 4 copper bars as mentioned in Para 3.5 of this WI is to be followed in induction brazed rotors as evident from above snap.

  • Press punching as mentioned in para 3.10 of this WI should be followed in practice.
  • Steel tape binding as mentioned in para 3.15 of this WI should be  done.
  • There are two types of rotors being manufactured:- MIG welded and Induction brazed. There is no WI issued for the latter.
  • Knowledge of this WI is OK among the staff.


CEE during his inspection of TM shop today asked about BRC shed buffer height case. He was informed about the NC raised by inspection wing.